Indianapolis Sanitary District Standards
-
On July 12, 2006, the Board of Public Works adopted new Sanitary District Standards for Indianapolis. This manual provides the design and construction standards for laterals and sanitary sewer facilities constructed within the Indianapolis Sanitary District. Included are submittal requirements and procedures for the issuance of Approvals and Permits, and the requirements and procedures for inspection, testing, and final acceptance of
sanitary sewer facilities.
Click here to download the full Sanitary Standards Manual
(Adobe Acrobat Reader Required)
Table of Contents (Updated 9.26.06)
CHAPTER 100 POLICIES AND PROCEDURES
- Section 101 Introduction
- Section 102 General Procedures and Requirements Applicable to All Permits
- Section 103 Laterals - Procedures and Requirements
- Section 104 Sanitary Sewer Facilities - Procedures and Requirements
- Section 105 Sanitary Sewer Construction Inspection and Acceptance Procedures
CHAPTER 200 DESIGN
- Section 201 Lateral Design
- Section 202 Gravity Sanitary Sewer Design
- Section 203 Sewer Structures - Manholes
- Section 204 Other Requirements
CHAPTER 300 MATERIALS
- Section 301 General
- Section 302 Sanitary Sewer Pipe Material
- Section 303 Laterals
- Section 304 Force Main Material
- Section 305 Manhole Material and Appurtenances
CHAPTER 400 INSTALLATION
- Section 401 Installation Requirements Applicable to Sanitary Sewer, Force Mains and Laterals
- Section 402 Installation Requirements for Specific Laterals
- Section 403 Installation of Precast Manholes, Wet Wells, Valve Vaults or Other Appurtenant Structures
- Section 404 Trenchless Installation
- Section 405 Erosion Control, Site Restoration and Safety
CHAPTER 500 LIFT STATIONS AND LOW PRESSURE SYSTEMS
- Section 501 Requirements Common to Both Lift Stations and Low Pressure Systems
- Section 502 Lift Station Design
- Section 503 Lift Station Equipment and Operating Requirements
- Section 504 Low Pressure Pump Stations and Appurtenances
CHAPTER 600 TESTING
- Section 601 General
- Section 602 Gravity Sanitary Sewer Testing Requirements
- Section 603 Force Main Testing Requirements
- Section 604 Manhole Testing Requirements
- Section 605 Lift Station Testing
APPENDICES
- Appendix A Fees
- Appendix B Average Daily Flow Estimates
- Appendix C Inspection Forms
- Air Test Data Sheet
- Sewer Manhole Test Report
- Sewer Force Main Test Report - Hydrostatic Leak Test
- Sewer Force Main Test Report - Alternate Test Method
DETAILS
Standard Detail Sheets-Includes All Details -
Sheet 1*
Sheet 2*
Click here to download all Sanitary Standards Details
Level 3 Lift Station Standard Detail Sheets*
Level 2 Lift Station Standard Detail Sheets*
Low Pressure System Standard Details*
MISCELLANEOUS FORMS
Required Forms:
Design Summary*
Variance Request Form*
Optional Forms:
Checklists are provided to assist the applicant/engineer with their design and submittal. Submitting the checklists is not a requirement for an approval or a permit. The checklists are used by staff when reviewing plans.
Submittal Checklist*
Sanitary Sewer Review Checklist
DIGITAL DATA SUBMISSION STANDARDS
Introduction
Digital Data Submission Standards
CLARIFICATIONS
Updates coming in 2009.
LINKS TO ADDITIONAL INFORMATION
Wasteload Allocation Report
*The document can be edited and saved with Adobe Reader 5.0, Adobe Acrobat 6.0+ Standard and Adobe Acrobat 6.0+ Professional. The document can be edited, but not saved, with Adobe Reader 7.0.